Instruction Manual

Troubleshooting 49
Table 5-4 Piston Replacement Wear Limits
Chamber Piston Size Diameter Wear Limit
1-cc 6.22mm (0.245-inch)
2-cc 9.40mm (0.370-inch)
" NOTE Wear may be uneven. Measure piston diameter at several places, especially bottom tip.
Table 5-5 Matched Cartridge Clip and Stopcock
Syringe/Cartridge Clip P/N Matching Stopcock P/N
03-1280-00 42-0080
03-1280-01 42-0083
Table 5-6 Dispense Tip and Recommended Flow Rates.
Maximum Recommended Flow Rate (mg/s) *
Dispense Tip
15 kcps (Typical for cavity Fill) 50 kcps (Typical for cavity Fill)
14 gage conical 100 + 300 +
15 gage conical 100 + 300
16 gage conical 100 + 200
18 gage x ¼-inch 100 + 100
18 gage x ½-inch 100 + 50
20 gage conical 100 + 140
20 gage x ¼-inch 50 25
20 gage x ½-inch 25 15
21 gage conical 100+ 100
21 gage x ¼-inch 25 15
21 gage x ½-inch 15 10
22 gage conical 90 70
22 gage x ¼-inch 10 Not recommended
22 gage x ½-inch 5 Not recommended
23 gage conical 25 20
23 gage x ½-inch 5 Not recommended
23 gage x ½-inch Not recommended Not recommended