Instruction Manual

Operation 27
10. Flip the orange locking lever on the pump all the way up. See Figure 3-15.
! This is the unlocked position.
11. Slide the pump all the way down the track of the dovetail receiver assembly on the
dispensing head.
! The bottom surface of the pump should rest against the dovetail mating stop at the
bottom of the dovetail assembly. See Figure 3-15.
12. Flip the orange locking lever 190° (down) to lock the pump into place.
CAUTION! Make sure that the pump is seated properly, flush against the stop at the bottom
of the dovetail assembly.
Figure 3-15 Installing the DP-3000
" NOTE If your DP-3000 is not equipped with the Quick Release Bracket, refer to the Installation
section for standard bracket installation instructions.
Orange Lockin
g
Leve
r
Dovetail
Matin
g
Sto
p