Instruction Manual

14 Installation
Figure 2-8 Valve Cable and Hose Connections (Axiom X-1020 Series)
To Install the DP-3000 with a Standard Bracket:
This procedure can be used for installing a DP-3000 with a standard bracket on a Millennium, Century or
M-2000 Series dispensing system.
1. Remove the currently installed fluid dispensing pump and bracket assembly.
! Refer to the installation/removal procedures in the manual for the currently
installed pump.
2. Use the Phillips-head screwdriver to loosen the screws on the Height Sensor bracket, and
remove the Height Sensor from the old bracket.
! The M-2000 has three screws; all other systems have two.
! If the Height Sensor includes a bracket spacer, remove the bracket spacer.
3. Configure the DP-3000 with a dispensing chamber, stopcock, desired syringe size, proper
Luer fittings, syringe clip, cartridge sleeve, if necessary, and needle as required for your
application. Refer to the Operation section for instructions.
4. Slide the DP-3000 pump assembly into the Z-head slot on the valve mount plate.
5. Align the top of the DP-3000 flush with the top of the Z-head slot.
6. Secure the DP-3000 by tightening the set screws on the right side of the Z-head slot using
the 5/64-inch hex key.
7. Attach the Height Sensor to the DP-3000.
! When using a Height Sensor Model HS-RT, you must install the adapter bracket first.
8. Connect the valve power cable and pneumatic hoses to the proper connectors, depending on
your specific dispensing system. (See Figure 2-5 for Millennium and Century Series
connections. See Figure 2-7 for M-2000 Series connections.)
9. Configure the Fluidmove software as described in “Software Configuration” later in
this section.
Syringe Receiver
Head
(
Clear
)
Valve Pressure
(
Blue
)
Stopcock Pressure
(Black)
Height Sensor
Valve Power Cable