Installation Owner's manual
System
Power-Up
8
If necessary, refer to Front View Features in this guide to identify Dispensing System
components.
1. Verify that the Main Power Cable is connected to the Main Power Inlet and the facility
power source.
2. Verify that the facility air is at the recommended pressure level and connected to the
Main Air Pressure Regulator Inlet. Refer to the DispenseMate 580 Series User
Guide for additional information.
3. Turn the Main Power Circuit Breaker on the back of the Dispensing System to the
ON (I) position.
4. The System Computer should begin the boot up sequence.
5. Check the EMO button to see if it has been activated. If it has been activated,
deactivate it by turning the red knob counterclockwise until the knob pops out.
6. Make sure the Interlock signal is not interrupted. Close the Dispensing System
enclosure if applicable.
7. Press the ON (l) button on the front panel.
8. The Dispensing System should be in a powered-up state and the digital gauges and
green power button should be on. If not, make sure the power cable is properly
connected to the Dispensing System and to an active facility power source.