Installation Owner's manual
Pneumatic
Connections
Connect the air supply to the ΒΌ-inch NPT quick-disconnect fitting at the facility air
connection. Refer to the Specifications section of the DispenseMate 580 Series User
Guide for additional information on System specifications.
To connect Facility Air Supply:
1. Attach a quick-disconnect air fitting (customer supplied) to the facility air hose.
2. Connect the facility air hose to the Main Air Pressure Regulator Inlet.
3. Connect the outlet of the Main Air Pressure Regulator to the Main Air Inlet on the
rear of the Dispensing System.
"NOTES The maximum air supply pressure should not exceed 100 psi (689 kPa).
Refer to the DispenseMate 580 Series User Guide for additional information
on pneumatic diagrams.
6
WARNING! CAUTION!
All System Pneumatic Connections should be checked before the
Main Air is connected.
Facilities
Power
Connection
7
WARNING! CAUTION!
Make sure your facility meets all requirements listed in the
Specifications section of the DispenseMate 580 Series User Guide.
Failure to meet these requirements could result in serious bodily
injury to personnel and damage to the Dispensing System.
CAUTION! This procedure should only be performed by a trained service
technician.
To connect Facility Power:
1. Unpack the Main Power Cable and remove all packing material including plastic
wrappers and tie wraps.
2. Plug the female end of the Power Cable into the Main Power Inlet on the back of the
Dispensing System. Plug the male end of the Power Cable into the facility power
source.
Factory Air
Supply to Quick
Disconnect
Main Air Inlet
Main Air Pressure
Re
g
ulator Inlet
Main Power
Inlet