44 Maintenance
4. Tension the Z-axis cables as follows:
a. Remove the Tooling Plate.
b. Manually push the Dispensing Head down.
c. Loosen the two Z-axis tensioner block screws (Figure 5-5).
d. Manually move the Dispensing Head up and down the full length of the axis. Repeat
three to five times.
e. Tighten the tensioner block screws.
5. When finished, replace the axis covers, tighten the screws and reattach the Tooling Plate.
Item Description
1 X-Axis Tensioner Block Screws
2 Y-Axis Tensioner Block Screws
3 Z-Axis Tensioner Block Screws
Figure 5-5 Tensioning the Cables
1
2
3