Manual

Maintenance 43
8. Put the tip of the grease syringe against the access hole and pump the grease syringe once or
twice to inject an ample amount of grease into the housing.
! The housing is full when grease comes out of the ends.
9. Spread the excess grease along the length of the X-Axis linear guides.
10. Repeat Steps 5 to 7 for the Y and Z-axis linear guides.
Figure 5-4 Lubricating the XYZ-Axis Linear Guides
Tensioning the Cables
" NOTE When performing this procedure, loosen the tensioner block screws, DO NOT
remove them.
1. Remove the X- and Y-axis covers as described previously in this section.
2. Tension the X-axis cables as follows:
a. Loosen the two X-axis tensioner block screws (Figure 5-5).
b. Manually move the Dispensing Head to the left and then to the right the full length of the
axis. Repeat three to five times.
c. Center the Dispensing Head along the X-axis and tighten the tensioner block screws.
3. Tension the Y-axis cables as follows:
a. Loosen the two Y-axis tensioner block screws (Figure 5-5).
b. Manually move the Tooling Plate to the back and then to the front the full length of the
axis. Repeat three to five times.
c. Center the Tooling Plate and tighten the tensioner block screws.