Manual
42 Maintenance
Item Description
1 Tooling Plate
2 Y-Axis Cables
3 Z-Axis Cables (inside)
4 X-Axis Cables (inside)
Figure 5-3 Mechanical Drive Cables
Lubricating the XYZ-Axis Linear Guides
" NOTE To perform the following procedure, you will need Asymtek Grease Kit P/N 7203262.
The kit contains a grease syringe.
1. Remove the X- and Y-axis covers as described previously in this section.
2. Load the grease cartridge into the grease syringe.
3. Purge the air from the grease syringe by dispensing grease until a solid stream flows from the
syringe.
4. Using the Position Controls, move the Dispensing Head to the front of the dispensing area
and lower it as much as possible.
! The needle and Height Sensor probe should not touch the substrate.
5. Turn OFF the Main Power Switch.
6. Locate the small access hole on the X-Axis bearing housing. See Figure 5-4.
7. When finished, replace the axis covers and tighten the screws.
1
4
3
2