Manual
40 Maintenance
Draining the Water Trap
Because the facility air supply may contain moisture that can damage the dispensing system, the
DispenseMate is equipped with a water trap that condenses this moisture before it enters the pneumatic
system. The operator or technician must drain the water trap weekly or whenever it is full.
Tools and Materials Needed:
• Box wrench
• Container for waste water
To drain the Water Trap:
1. Locate the water trap at the rear of the system.
2. Shut off facility air pressure and using a box wrench, disconnect the facility air supply from
the Main Air Pressure Regulator Inlet.
3. Hold a container under the water trap to catch the water and open the water drain knob by
turning counterclockwise.
4. After the trap has been drained, close the water trap drain knob by turning clockwise.
5. Reconnect the facility air supply to the Main Air Pressure Regulator Inlet.
Item Description
1 Main Air Pressure Regulator Inlet
2 Water Trap
3 Drain Knob
Figure 5-1 Draining the Water Trap
3
1
2