30 Operation
Using the Mouse
To operate position controls with the Mouse:
1. In the FmNT Main Window, click on
Jog.
! The Position Controls dialog box opens. See Figure 4-3.
! The Dispenser radio button will be selected, indicating that the Dispensing Head
position controls are active.
Item Description
1 Y-axis Controls (forward and back movement)
2 X-axis Controls (side to side movement)
3 Dispenser Radio Button
4 Home Button
5 Z-axis Controls (up and down movement)
Figure 4-3 Dispensing Head Position Controls
" NOTE Position Controls can be accessed from the FmNT Main Window, the Production Window,
the Run Window, the Programming Window, and the Tools Window. For additional
information on Position Controls, refer to the FmNT User Guide or Online Help.
2. Dispensing Head position controls (Figure 4-3) operate as follows:
! On the X-Y control panel, the arrows pointing to the Left move the Dispensing Head to
the left and the arrows pointing to the
Right move it to the right.
! On the X-Y control panel, the arrows pointing Up move the Tooling Plate toward the front
of the dispensing area and the arrows pointing
Down move it toward the back.
! On the Z control panel, the arrows pointing Up move the Dispensing Head upward and
the arrows pointing
Down move it downward.
5
1
2
4
3