26 Installation
Electrical Connections
The dispensing system requires 1 kw of single-phase power at 100, 120, 220, or 240 VAC.
" NOTE Board wiring connections are installed in the factory before the product is shipped. Refer
to the Specifications section for more information on electrical requirements. Refer to
Appendix A for information on available electrical diagrams. Contact your Asymtek
representative for requirements on your particular system.
Connecting Power and Air Supply
WARNING! CAUTION!
Make sure that your facility meets all requirements listed the Specifications
section. Failure to meet these requirements could result in serious bodily injury to
personnel and damage to the dispensing system.
CAUTION! This procedure should only be performed by a trained service technician.
To connect the facilities power and air supply:
1. Unpack the Main Power cable and remove all packing material including plastic wrappers
and tie wraps.
2. Plug the female end of the power cable into the Main Power Inlet on the back of the
dispensing system. Plug the male end of the power cable into the facility power source. See
Figure 3-5.
Item Description
1 Main Air Inlet
2 Main Power Inlet
3 Main Air Pressure Regulator Inlet
Figure 3-5 Connecting the Facilities Power and Air Supply
3. Attach a quick disconnect air fitting (customer supplied) to the facility air hose.
4. Connect the facility air hose to the Main Air Pressure Regulator Inlet.
5. Connect the outlet of the Main Air Pressure Regulator to the Main Air Inlet on the rear of the
dispensing system.