Manual

Introduction 7
Dispensing Area
The Dispensing Head, Valve, Camera, Height Sensor and Tooling Plate are located in the Dispensing
Area (Figure 1-3).
1. Camera and Lens
The compact, high resolution, black and white Camera and its vibration resistant lens are part of the
Vision System. They are mounted on the Dispensing Head and are used to view work surfaces.
2. Dispensing Valve
The Dispensing Valve controls or regulates the flow of material from a pressurized reservoir, such as
a syringe. Devices include Valves, Pumps, and Jets.
3. Tooling Plate
The Tooling Plate secures the workpiece for batch system operations.
4. Height Sensor
The Height Sensor is a device that measures substrate height and sends a signal to the system
Computer. The height information is used to position the dispensing needle at an exact distance
above the workpiece surface.
Item Description
1 Camera
2 Dispensing Valve (DJ-9000 shown)
3 Tooling Plate
4 Height Sensor
Figure 1-3 Dispensing Area (Close-up)
1
2
3
4