Instruction Manual
Introduction 1
1 Introduction
1.1 Overview
This manual describes the software setup and sequence for operating the Vacuum Assisted Priming
Routine (VAPR). VAPR is designed for use with the DJ-9000 Series DispenseJet and is available on the
M-2000 and S-900 Series Dispensing System platforms. Refer to the DJ-9000 Owner's Manual
(P/N 7200530) for detailed instruction on valve operation.
1.2 System Requirements
Dispensing System: Spectrum Series S-900 or Millennium M-2000
Series Dispensing Systems
Dispensing Valve: DJ-9000 DispenseJet
Software: Fluidmove for Windows XP (FmXP)
Fluidmove for Windows NT (FmNT)
Fluidmove Version Version 5.3 or higher
WARNING! CAUTION!
DO NOT operate the dispensing system unless you have been trained to do so.
Operating the dispensing system without proper training may result in personal
injury or dispensing system damage.
1.3 Theory of Operation
Trapped air in a dispensing valve influences the amount of fluid deposited. The Vacuum Assisted Priming
Routine utilizes vacuum at the purge station to evacuate air from the DJ-9000 fluid chamber prior to
introducing fluid.
WARNING! CAUTION!
Consult the Material Safety Data Sheet (MSDS) for all fluids used with the
dispensing system. The MSDS provides material usage instructions, disposal
instructions, and safety precautions.