User Manual
10 Installation
To install the DJ-9500:
1. Mount the DJ-9500 on the dovetail bracket and tighten with the 4-mm hex wrench.
2. Make the electrical connections according to the appropriate machine configuration shown
in Figure 4-1 and Figure 4-2.
3. Connect the pneumatic hoses as shown in Figure 4-1 and Figure 4-2. You should hear a
click when the hose is inserted properly.
The black hose connects to valve air.
The transparent green hose is used for nozzle cooling in elevated temperature
environments. Refer to the Fluidmove User Guide for software control setup of the
nozzle cooler. You can download the manual from:
http://www.nordsonasymtek.com
The green hose (if installed) is used for valve body cooling in elevated temperature
environments.
NOTE Verify that the cables and connections are secured adequately to account for the motion
of the robot.