Manual

Maintenance and Service 39
To adjust the Micro-adjustment:
The micro-adjustment setting regulates the fluid volume for the dot or line. The higher up the setting, the
more fluid is dispensed.
NOTE The preload screw must be adjusted before performing this procedure. Refer to the “To
adjust the Preload:procedure earlier in this section.
1. Using a 0.05-inch hex key, loosen the setscrews on the preload screw.
2. Rotate the inner micro-adjustment column so the numbered markings face the solenoid valve.
3. Using the 0.05-inch hex key, tighten the preload set screws, locking the preload screw in place.
4. Using your fingers, loosen the micro-adjustment lock nut by turning it counterclockwise.
5. Turn the outer micro-adjustment collar down and clockwise until it stops.
CAUTION! Do not continue to turn the outer micro-adjustment collar once it stops, or you may
damage the DispenseJet.
6. Use a 1.5-mm hex key to loosen the micro-adjustment collar set screw.
7. Raise and turn the outer micro-adjustment collar clockwise so that the vertical zero (
0) marking
aligns with the vertical centerline on the inner micro-adjustment column.
NOTE The bottom of the outer micro-adjustment collar should align with the horizontal zero
(
0) marking on the inner micro-adjustment column.
8. Using the 1.5-mm hex key, tighten the micro-adjustment collar set screw.
9. Rotate the outer micro-adjustment collar counterclockwise to set the micro-adjustment to the
desired parameter.
NOTE Every ten marks on the outer micro-adjustment collar equal 0.10-mm. For example, a
movement of five marks equals 0.05-mm relative to your starting position. Only the
increment marks on the outer micro-adjustment collar are relevant for adjustment.
10. Finger-tighten the micro-adjustment lock nut.