7 Additional Information
Recommended Facility Items
In addition to the supplied accessories and tools, it is recommended that the following items be available
at your facility:
Personal Protective Equipment recommended in applicable MSDS
Bench Lamp and Magnifier Set
Ultrasonic Cleaning System
Airgun and compressed, dry air
Appropriate fluid collection and disposal container
Solvent appropriate for the fluid used
O-ring type lubricant
Disposable towels, cleaning swabs and brushes
WARNING! The outside of the jet should be cleaned only with a soft cotton or cellulose cloth.
The cloth can be moistened with alcohol when fluid buildup on the jet is
excessive. Do not use very wet cloths, and never pour solvent or water directly
onto the jet. Do not submerge the jet in cleaning agent. The drive could be
destroyed if liquid penetrates it. Only the components of the DJ-100 that come
into contact with the processed fluid need be cleaned.
WARNING! The cleaning fluid that should be used to purge and clean the equipment is a
factor of the fluid in the jet. The cleaning intervals also depend on the dispensed
fluid and can be found on the respective data sheet. Mix together the cleaning
fluid and the dispensed fluid outside of the jet to verify solubility.
Return Material Authorization
Obtain a Return Material Authorization (RMA) from Asymtek Customer Service before returning parts.
18