Owner's manual

Status Signals and Fault Codes
The LEDs on the front of the CON100 control unit indicate status signals as well as faults.
Table 6-2 provides an overview of the various indications:
Table 6-2 CON100 Status Signal and Trouble Codes
Categories:
FD: Cause = Disp
Power Temp P400 Akku Load Possible cause for Voltage FB: Cause = User
Malfunction managment
LED LED LED LED LED malfunction PIN 13 B = normal
On On/out Out Out On/out Power Supply Amplifier 24V B
Module normal and
Amplifier Module
connected with jet
If heater is used and
choosen temperature is
reached, LED Temp is On
Flash¹ Out Flash¹ Out On/out Malfunction heater 0V Check cable and plugs to jet.
Change jet. Or use
temperature setting below
20°C / 40°C to continue.
FD
Chosen temperature
is >20°C / 40°C
(Potentiometer or external)
Flash¹ Flash¹ Flash¹ Out On/out No jet connected to
amplifier module or no
ENA signal
0V Connect jet. Check cable
and plugs to jet.
FB
Out Out Flash¹ Out On/out Piezoelectric drive
damaged
or failure jet power supply
0V Change jet. Check cable
and plugs to jet.
FD
Out Flash¹ Out Out On/out Failure temperature sensor 0V Check cable and plugs to jet.
Change jet. Or use
temperature setting below
20°C / 40°C to continue.
FD
Chosen temperature
is >20°C / 40°C
(Potentiometer or external)
Out Flash¹ Out Out On/out Jet without heater
connected
0V Use temperature setting
below 20°C / 40°C to
continue.
FB
Chosen temperature
is >20°C / 40°C
(Potentiometer or external)
Out Out Out Flash² On Power supply voltage
is too low
(between 8 to 21 Volt)
0V Check reason and use
correct voltage
FB
Out Out Out Flash² Out Power supply completely
down
0V Jet closed by battery. Start
up power supply again
immediately or release fluid
pressure on jet
FB
On Flash
3
Out Out On/out Heater deactivated by
external signal
24V As long as external signal is
high, heater is deactivated
B
Flash¹ - LED - 0.333 s ON / 0.333 s OFF Flash² - Short flash with long break time to save energy Flash³ - LED - 0.12 s ON / 0.12 s OFF for 2
times then break 1.5 s
CAUTION! All malfunction categories (FB and FD) have to be cleared by resetting the
amplifier module. To reset the amplifier module, please switch off the main power
switch of the unit and turn it on again after a few seconds. Disconnect the fluid
pressure hose before turning off the power.