Operation
(contd.)
Purging Flux
Perform these steps to purge flux from the system:
1. Turn the FLUID SELECT valve (4) to IPA.
2. Actuate the dump valve on the DG-1000
dispenser. Purge until flux thins out or IPA
appears. Close the dump valve.
3. Manually actuate the DG-1000 dispenser solenoid
valve until solvent flows out of the DG-1000
dispenser.
Maintenance
Clean the filter (7) periodically:
1. Adjust the FLUID PRESSURE ADJUST
regulator (3) until 0 psi appears on the FLUID
PRESSURE display (5).
2. Turn the FLUID MODE valve (1) to FILL.
3. Place a container under the filter (7).
4. Remove the filter cap (11).
5. Remove the filter element (9) from the filter (7) and
clean with a compatible solvent. Inspect the
following:
S the filter (7) for foreign materials
S the filter element (9) for damage
S the filter gasket (10) for damage
6. Replace the filter element and gasket, if
necessary.
NOTE: A clean filter may cause an air bubble in the
fluid line. If this occurs, perform the
Filling the System
with Flux
procedure.
7. Install the filter element (9) and gasket (10) on the
filter (7).
8. Install the filter cap (11) and tighten securely.
9. Turn the FLUID MODE valve (1) to RUN.
10. Adjust the FLUID PRESSURE ADJUST
regulator (3) until 5 psi appears on the FLUID
PRESSURE display (5).