Instruction Manual

DG-1000 Dispenser
8
E 1998 Nordson Corporation
All rights reserved
107 156C
Issued 11/98
Manual 12-35
Table 2 Operation Default Parameters
Function Parameter
Pb1 (Proportional band 1) Factory Default
rE1/lt1 (Reset 1/Integral 1) Factory Default
rA1/dE1 (Rate 1/Derivative 1) Factory Default
Ct1 (Cycle time 1) Factory Default
Pb2 (Proportional band 2) Factory Default
rE2/lt2 (Reset 2/Integral 2) Factory Default
rA2/dE2 (Rate 2/Derivative 2) Factory Default
Ct2 (Cycle time 2) Factory Default
ALO (Alarm low) Factory Default
AHI (Alarm high) Factory Default
CAL (Calibration offset) Factory Default
AUt (Auto-tune) Factory Default
NOTE: If another temperature controller is used, refer to the appropriate
controller manual.
1. Start the system using the procedure provided in your system
manual.
2. Make sure that the dispenser has a nozzle on the extension. The
nozzle must be tightened to 25 NSm (19 in.-lb).
3. Place a small waste container under the extension to catch coating
material. Activate the purge program.
4. After running the purge program, remove the waste container.
5. Refer to the
DG-1000 Dispense
r Operators Card
, Operating
Parameters
,
to determine the proper nozzle to use. Install the proper
nozzle on the dispenser.
Setting the Watlow
Temperature Controller
(contd)
Startup