Quick Operations User Manual
4 Introduction
Control Panel
Below are descriptions of C-740/C-741 Series Dispensing System Control Panel buttons as shown in
Figure 1-2.
" NOTE Refer to the Operation section for detailed descriptions of all Control Panel buttons
and functions.
1. Start/Stop Buttons
The Start and Stop buttons are push buttons located on the Control Panel. They control the power
to the dispensing system. The Start button glows green when pushed, and continues to glow until
the Stop button or Emergency Machine Off (EMO) button is pressed.
2. Motion Controls
The Motion Control buttons allow you to manually move the Dispensing Head or the Conveyor.
Press the Robot Enable button to enable communication with the Dispensing Head. To enable
communication with the Conveyor Controller, press the Convyr Enable button.
3. Interlock Keyswitch
The Interlock Keyswitch activates and deactivates the Safety Interlock System. Refer to the Safety
section for additional information.
4. Emergency Machine Off (EMO)
Activating the EMO vents all pressure in the pneumatic system, de-energizes the Robot motors, and
cuts power to all system components except the Computer and Monitor. Refer to the Safety section
for additional information.
5. ESD Grounding Strap Connector
Grounding straps worn by the operator or technician plug into this jack to prevent electrostatic
discharge (ESD) damage to workpieces and dispensing system electronics during dispensing
operations and servicing.
Item Description Item Description
1 Start/Stop Buttons 4 EMO Button
2 Motion Controls 5 ESD Grounding Strap Connector
3 Interlock Keyswitch
Figure 1-2 C-740/C-741 Control Panel
5
1
3
2
4