Quick Operations User Manual

44 Operation
Daily Routine Procedures
Table 3-6 contains a brief description and instructions for routine procedures that should be performed on
a daily basis before and after operating the dispensing system.
Table 3-6 Daily Routine Procedures
Procedure Description
STARTUP
Clean Fluid Filter
Check the fluid filter and clean if necessary. Refer to “
Cleaning the
Fluid Filter”.
Check Main Air Pressure
Ensure that the main air pressure is properly adjusted. If necessary,
adjust the main air pressure as described in “
Main Air Regulator and
Gauge” in the
Operation section. Record the proper setting on the
Daily Routine Checklist for daily reference.
Check Fluid Pressure
Ensure that the fluid pressure is properly adjusted. If necessary, adjust
the fluid pressure as described in “
Fluid Pressure Regulator and
Gauge” in the
Operation section. Record the proper setting on the
Daily Routine Checklist for daily reference.
"NOTE Refer to the manual for your specific fluid applicator
for appropriate fluid pressure settings.
Verify Exhaust Connection
Verify that the Exhaust Vent is properly connected to the facility
exhaust system ductwork. Refer to the Century C-740/C-741
Installation, Operations, and Maintenance Manual.
Fill Fluid Reservoir
Fill the Fluid Reservoir as described in
Filling the Fluid Reservoir”.
Fill Solvent Cup
Make sure that the solvent cup is filled with a clean supply of the
appropriate solvent and is properly placed for the selected coating
program.
Verify Material Temperature
Verify the material temperature, if applicable.
Perform Characterization
Perform a characterization if necessary. See “
Characterization” later in
this section.
SHUTDOWN
Remove Workpieces
Remove all workpieces and foreign objects from the dispensing and
conveyor areas.
Flush Fluid System
Flush the fluid system. Refer to “
Changing Material/Flushing Fluid
System”.
Clean Dispensing System
Clean all surfaces of the dispensing system (doors, side panels,
control panel, part sensor, etc.).
Clean Nozzle
Refer to the manual for your specific fluid applicator for instructions.