Quick Operations User Manual
Operation 33
Power Buttons
Table 3-1 Power Buttons
Button/Switch Appearance Function
EMO Button
Located at the right end of the Control Panel, the
large, red Emergency Machine OFF (EMO) button
cuts electricity to the Power Manager and stops all
system motion.
Pressing the EMO vents all pressure in the pneumatic
system, de-energizes the robot motors, and cuts
power to all system components except the Computer
and Monitor.
System START/STOP
Buttons
I
The Start and Stop buttons are located on the Control
Panel and control power to major system components.
The Start (I) button glows green when pushed and
continues to glow until the Stop (0) button or
Emergency Machine OFF (EMO) button is pressed.
" NOTE During power-up, there is a 60 second
delay to allow the dispensing system
to vent properly.
Download Program Controls
Table 3-2 Download Program Controls
Button/Indicator Function
ABORT
ABORT halts a production run. After you press the ABORT button,
its red LED lights to indicate that the currently loaded program is
discontinued.
After a program is aborted you must press RESET and then FIND
HOME before you can restart the program.
VVV
PAUSE
PAUSE temporarily stops a production run. When its yellow LED
indicator is ON, the system is paused. You can pause a production
run at any time.
To resume dispensing, press PAUSE again. When the LED
indicator turns OFF, the system resumes dispensing.
9
8
7
6
5
3
2
1
4
0
START
PROGRAM
9
8
7
6
5
3
2
1
4
0
9
8
7
6
5
3
2
1
4
0
START
PROGRAM
Program selection lets you program the dispensing system and
download a pre-programmed set of instructions.
" NOTE This feature is not used with ECXP.