Instruction Manual

Power-up and Testing 5-3
5. Turn the Computer Power Switch to the ON (I) position.
6. Check the EMO button to see if it has been activated. If it has been activated, deactivate it by
turning the red knob clockwise until the knob pops out.
7. Press
Start on the Control Panel (Figure 5-2).
" NOTE The dispensing system turns on after an approximate 60-second vent air time delay.
Verify that the red Vent Air LED on the control panel is blinking. If it is on and not
blinking, the exhaust is inadequate.
! The dispensing system should be in a powered-up state. If not, make sure the power cord
is properly connected to the dispensing system and to an active facility power source.
! The system computer should begin the boot up sequence.
8. Press
System Status Reset and Conveyor Status Reset on the Control Panel.
9. Press
Find Home on the Control Panel.
! The Robot should move to the extreme front left corner of the dispensing area.
Item Description
1 Start Button
2 Stop Button
3 Find Home Button
4 Conveyer Status Reset
5 System Status Reset
6 Vent Air LED
7 EMO
Figure 5-2 Control Panel Buttons
3 4
5
7
1
6
2