Instruction Manual

Installation 4-13
4.12 Connecting Power and Air Supply
WARNING! CAUTION!
Make sure that your facility meets all requirements listed in Section 11 -
Specifications. Failure to meet these requirements could result in serious bodily
injury to personnel and damage to the dispensing system.
CAUTION! This procedure should only be performed by a trained service technician.
Tools and Materials Needed:
Main Power Cable
Quick Release Air Hose Nozzle
To connect the facilities power and air supply:
1. Unpack the main power cable and remove all packing material including plastic wrappers and
tie wraps.
2. Plug the female end of the power cable into the main power inlet on the lower left side of
the dispensing system. Plug the male end of the power cable into the facility power source
(
Figure 4-5).
CAUTION! Switch the Main Circuit Breaker to the OFF (0) position before proceeding.
3. Locate and attach the quick disconnect air nozzle to the facility air hose.
4. Connect the facility air hose to the main air inlet connector on the back right side of the
dispensing system.
5. Install a damper at the exhaust duct.
6. Connect the facility exhaust ventilation system ductwork to the exhaust vent duct
(
Figure 4-5).
7. Adjust airflow to a minimum of 400 scfm with the Conveyor doors closed.