Instruction Manual
4-4 Installation
4.5 Unpacking the Dispensing Area
CAUTION! If the dispensing system is being installed in a clean room, remove all packaging
material and follow facility-recommended procedures before moving components
into the clean room.
To unpack the dispensing area:
1. Remove all perimeter packaging material from the dispensing area.
2. Remove all tie wraps, tape, foam packaging material, and warning tags from the Dispensing
Head and Conveyor (C-740) or Tooling Plate (C-741).
"NOTE Location of packaging materials to be removed is indicated by the presence of red
warning tags. The amount, type, and arrangement of packaging materials will depend on
your system’s configuration.
4.6 Unpacking the Accessories Crate
"NOTE The contents of the accessories crate will vary depending upon the options ordered with
your dispensing system.
Tools and Materials Needed:
• Flat Bar
• Pen or Pencil
• Appropriate Personal Protective Equipment
To unpack the accessories crate:
1. Use the flat bar and hammer to remove the crate lid.
2. Open the bag inside of the crate.
! As you unpack each item inside of the box, identify the item, locate it on the shipping list,
and place a check mark next to the item.
! You may need to open the item in order to identify it. Once it has been identified, return
the item to its original box or bag.
3. If any parts or accessories are missing, please contact Asymtek Technical Support.
4. Place each item from the accessories crate onto a cart for easy transport. If possible, place the
items next to the dispensing system onto which the items will be installed.