Instruction Manual
4-2 Installation
4.4 Uncrating and Placing the Dispensing System
CAUTION! Check the Tip & Tell and ShockWatch devices, both on the outside of the crate
and on the dispensing system, to make sure that the dispensing system has not
been dropped or tipped over. If either of these devices has been activated,
contact Asymtek Technical Support.
If the dispensing system is being installed in a clean room, uncrate the system,
unpack the accessories crate and remove all packaging material including
wrapping paper and tape from all parts and components before moving anything
into the clean room.
This installation procedure should only be performed by a trained service
technician.
Tools and Materials Needed:
• Adjustable Wrench • Hammer
• 7/16-inch Wrench • Flat Bar
• 9/16-inch Wrench • Forklift
• Appropriate Personal Protective Equipment
To uncrate and place the dispensing system:
1. Check the “Tip & Tell” and “ShockWatch” devices, both on the outside of the shipping crate
and on the dispensing system, to make sure that the dispensing system has not been dropped
or tipped. If any of these devices has been activated, contact Asymtek Technical Support.
2. Locate and remove the envelope on the outside of the shipping crate. Open the envelope
and locate the shipping list and uncrating instructions inside. Place the shipping list in a
safe location.
3. Referring to the uncrating instruction sheet, use the flat bar and hammer to remove the lid and
sides of the crate.
WARNING! CAUTION!
Personnel should wear gloves and safety glasses while removing the top and
sides of the crate. Sufficient personnel should be used to lift and control the crate
top and sides to prevent serious injury to personnel or damage to the dispensing
system. Refer to Section 2 - Safety.
4. Remove all packaging material from the perimeter of the dispensing system.