Instruction Manual

3-12 Component Description
3.8.12 Low Fluid Sensor (for external reservoir)
Located within the external reservoir, the Low Fluid Sensor triggers a Light Beacon display and software
warning message when the level of coating material is low. The sensor can be set to a level that provides
ample time to refill the reservoir before reaching an out-of-material condition.
3.8.13 Low Solvent Cup Sensor
The Low Solvent Cup Sensor triggers a Light Beacon display and software warning message when the
level of solvent in the cup is low. The software timer can be set to a level that provides ample time to
refill the cup before reaching an out-of-solvent error condition.
3.8.14 Material Change Over
This option allows you to switch air and fluid lines between two reservoirs and the fluid system without
physically disconnecting fittings and hoses. The Material Change Over System consists of tubing,
manually operated valves, controls, an extra reservoir, and all the fittings required for self-contained
material change over. The system allows you to switch from the use of coating material to solvent for
flushing the fluid lines and fluid applicator during extended shutdown. See
Figure 3-8.
Item Description
1 Manual Material Changeover Switching Mechanism
2 Fluid Reservoir (1 gallon)
Figure 3-8 Material Change Over Option
1
2
2