Instruction Manual
Safety 2-19
2.10.3 Electrical Fuses
Electrical fuses help prevent injury to personnel and damage to dispensing system electronic components
due to overload conditions. Century C-740/C-741 Series Dispensing System fuses are described in
Table 2-4.
" NOTE See Section 10 - Parts Replacement for fuse replacement instructions.
WARNING! CAUTION!
Electrical shock and fire can result if fuses are bypassed, incorrectly installed, or a
fuse with the wrong rating is used.
Table 2-4 Replaceable Fuse Descriptions
Fuse Location Mount Description
Power Entry Module (Conveyor
Controller)
Panel
The Main Line fuse is located in a box on the Conveyor
Controller Module This fuse prevents the module from
being damaged in case of a main power surge.
SMEMA Fuse (Conveyor
Controller)
Panel
The SMEMA fuse is located on the Conveyor Controller
Module. This fuse prevents the board from being
damaged in case of an I/O overload.
Robot Controller Panel
Located on the top right of the dispensing system are
two fuses. These fuses prevent the Robot Controller
from being damaged in case of a power surge.
Z-Head Panel
Located on the top left of the dispensing system, this
fuse protects the 38 VDC supply to the Z-head.