Instruction Manual

2-16 Safety
2.10.1.3 Interlock Recovery Light
The Interlock Recovery Light (Figure 2-9) is located on the Control Panel and is labeled Interlock
Recovery. When the light is ON, you can safely access the inside of the dispensing area. When the light
is OFF, accessing the inside of the dispensing area will cause a non-recoverable interlock shutdown
to occur.
Item Description
1 Find Home
2 Interlock Recovery Light
3 System Status Reset
Figure 2-9 Interlock Shutdown Recovery
2.10.1.4 Non-Recoverable Interlock Shutdown
When a non-recoverable interlock shutdown occurs, the motor power turns OFF, the system loses master
references, and the red “ABORT” System Status Indicator LED (Figure 2-10) illuminates. The program
WILL NOT be able to resume from where it stopped.
To recover from a shutdown triggered by the Interlock:
1. Close the doors or remove obstruction from Light Curtain (if installed).
2. Press the
System Status Reset button on the Control Panel. See Figure 2-9.
3. Wait three seconds and then press the
Find Home button on the Control Panel. See
Figure 2-9.
4. Restart your dispensing program. See 6.11 Loading a Program and 6.12 Running a Program.
1
2
3