Instruction Manual

2-14 Safety
2.10 Integrated Safety Systems
The C-740/C-741 Series Dispensing Systems have a built-in safety system that automatically protects
personnel from being injured by movement of the Dispensing Head and Conveyor. This system consists
of the following:
Safety Interlock System
Light Beacon
Electrical Fuses
2.10.1 Safety Interlock System
The Safety Interlock System consists of the following:
Safety Interlock Keyswitch
Interlock Door Sensors
Interlock Recovery Light
2.10.1.1 Safety Interlock Keyswitch
The Safety Interlock Keyswitch is located on the Control Panel (Figure 2-7). It is designed to restrict
access to the inside of the dispensing system, based on user-defined levels of operation. The Safety
Interlock has two modes: ON
(l) or OFF(0). Once an Interlock safety mode is selected, the key can be
removed to prevent an inadvertent mode change. The Safety Interlock is designed to work with either the
Door Sensors or with the Light Curtain.
" NOTE References that describe the front doors as “open” also pertain to situations where the
Light Curtain has been triggered by an intruding object.
Item Description
1 Interlock Keyswitch
2 System Status Indicator LED’s
Figure 2-7 Safety Interlock Keyswitch