Instruction Manual

Safety 2-11
2.8.1 Emergency Shutdown Situations
As a minimum, activate the EMO in the following situations:
WARNING! CAUTION!
In an emergency, failure to completely shut down power to the dispensing
system with the EMO can cause serious injury to the user and/or damage to the
dispensing system.
If anyone is in immediate danger of being injured by moving parts, hazardous materials, or
electrical shock.
If valuable dispensing system components or the workpieces are in danger of being damaged.
This can include:
- Physical damage to the dispensing valve or workpiece by unexpected Dispensing
Head movement.
- Electrical damage to the dispensing system.
2.8.2 Emergency Shutdown Recovery
WARNING! CAUTION!
Do not restart the dispensing operation until the condition that caused the
emergency shutdown has been corrected. Failure to comply could cause serious
injury to the user and/or serious damage to the dispensing system.
" NOTE If the Main Circuit Breaker has been tripped, you will need to restart the dispensing
system as specified in 5.3 Powering Up the System.
To recover after an emergency shutdown:
1. Open the front doors and clear the Conveyor of all workpieces.
2. Locate and remedy the cause of the emergency shutdown. If necessary, refer to Section 8 -
Troubleshooting.
3. Close the dispensing area doors.
4. Turn the EMO knob counterclockwise until it pops back into position.
5. Press the
Start (I) button on the Control Panel.
6. Press
Find Home on the Control Panel.
7. Restart your dispensing program. See 6.11 Loading a Program and 6.12 Running a Program.