Instruction Manual
2-6 Safety
2.6 Earthquake Precautions
2.6.1 Personnel
To prevent injury during an earthquake, all personnel should follow facility earthquake safety guidelines.
2.6.2 System Safe Mode
Your Century C-740/C-741 Dispensing System is designed to automatically relieve all hazardous
electrical, pneumatic, and hydraulic energy in the event that electrical power is lost due to an earthquake.
2.6.3 Movement
Your dispensing system must be secured to prevent movement that could cause injury to personnel and
damage to the system and surrounding areas during an earthquake. Each dispensing system Leveler
should be anchored to the floor with two bolts. See
Figure 2-1. The anchor joint (the point between each
anchor bolt and the floor) must be able to withstand at least 100 kg (220 lbs.) of pullout force.
Item Description
1 Screw
2 Leveler (foot)
3 Floor
Figure 2-1 Earthquake Precautions