Instruction Manual
1-16 Introduction
1.5.2.1 Right Rear View (Close-up)
Below are functional descriptions of C-740/C-741 Series Dispensing System components shown in
Figure 1-7.
1. Stop/Clamp Air Gauge (C-740)
The Stop/Clamp Air Gauge indicates the air pressure to which the Stop/Clamp Air Regulator is set.
The recommended setting is 206 to 275 kPa (30-40 psi).
2. Stop/Clamp Air Regulator (C-740)
The Stop/Clamp Air Regulator controls the air pressure supplied to the Stop Pins and Board Pins
on the Conveyor.
3. Reservoir Air Pressure Pneumatic Switch
The Reservoir Air Pressure Pneumatic Switch toggles the air supplied to the fluid reservoir ON
and OFF.