Instruction Manual

11-2 Specifications
11.3 Facility Requirements
Table 11-1 Facility Requirements
Facility Requirements
System Footprint 917 x 1041 mm (36 x 41 in.)
Compressed Air Dry; 40° F
Dew Point
80 to 100 psi (551 to 689 kPa), up to 85 l/min (3 scfm)
maximum, depending on configuration
Ventilation Air Exhaust
0.28 m
3
/s @ 25 mm water column (600 scfm @ 1.0 in.
water column)
Nitrogen Source
Required for moisture-sensitive materials – 80 to 100 psi
(551 to 689 kPa), up to 340 l/min (12 scfm)
Main Power Supply 100/120/220/240 VAC, 50/60 Hz, 10 A
Noise <70 dBA
System Weight 295 kg (650 lbs.)
Standards Compliance SMEMA, CE, FM
11.4 Drive System
Table 11-2 Drive System
Drive System
X/Y-Axes
Speed: 508 mm/sec (maximum)
381 mm/sec (default)
(20 in/sec)
(15 in/sec)
Control: Brushless DC stepper motor
Accuracy:
±125 microns at 3 sigma (±0.005 in.)
Z-Axis
Speed: 203 mm/sec (8 in/sec)
System Repeatability:
±0.025 mm (±0.001 in.)
System Resolution: 0.025 mm (0.001 in.)
System Accuracy:
±0.125 mm (±0.005 in.)
11.5 Conveyor
Table 11-3 Conveyor Specifications
Conveyor Specifications
Height from Floor 876 to 978 mm (34.5 to 38.5 in.)
Acceptable Board Width 58 to 400 mm (2 to 15.75 in.)
Edge Clearance 3.5 mm (0.14 in.)
PCB Thickness 7.6 mm (minimum) (0.02 in. minimum)
Warp 3 mm per 100 mm
running surface
(0.18 in. per 3.94 in.
running surface)
Chain Speed 254 mm/sec (default) (10 in/sec)
Flow Left to right (standard);
right to left (optional)