Instruction Manual
10-8 Parts Replacement
10.9 Replacing Fuses
The number of fuses may vary with the configuration of your system. All fuses are clearly identified.
Replacement fuse locations for the Century C-740/C-741 Series Dispensing Systems are shown in
22HFigure 10-10.
CAUTION! Always replace fuses with fuses of identical rating and size. Failure to do so will
not protect components from damage and may cause fire.
10.9.1 Replacement Fuses
Replaceable fuses for the Century C-740/C-741 Series Dispensing Systems are listed in 23HTable 10-1.
Table 10-1 Replaceable Fuses
Fuse Location
Part
Number
Qty. Rating Mount Type Size
55-5390
If connected to 100–
120 VAC, use 2 A fuse
5x20 mm
55-5380
1
If connected to 220-
240 VAC, use 1A fuse
Main Line
5x20 mm
Conveyor Controller
55-5336 1 1/8 A (125 mA) Panel 5x20 mm
55-5390
If connected to 100–
120 VAC, use 2 A fuse
Power Entry Module
55-5380
2
If connected to 220-
240 VAC, use 1A fuse
Panel 5x20 mm
Z-Head 55-5390 1 2A Panel 5x20 mm
CAUTION! Fuse replacement should only be performed by a trained service technician.