Instruction Manual

Parts Replacement 10-3
10.4 Cleaning and Inspection
Always clean the area made visible after a failed part is removed from the dispensing system. Inspect the
area for signs of what may have caused the part to fail. This may help prevent future part damage.
While removing parts that will be reinstalled, visually inspect them for damage. If found undamaged,
retain them for reinstallation. Replace damaged parts and hardware as appropriate.
10.5 Unpacking and Inspecting Replacement Parts
Replacement parts are shipped to distributor or Customer facilities in individual shipping cartons. Review
the packing slip to ensure that the correct parts were received. Contact Asymtek Technical Support if any
discrepancies are discovered.
Before unpacking your spare parts, visually inspect the carton for damage. If applicable, check the
ShockWatch and the Tip N’ Tell stickers for indications of improper shipping and handling. Inform the
freight carrier of any damage.
TIP Save shipping materials for returning failed parts.
10.6 Record Keeping
The type of service performed should be recorded in the dispensing system maintenance records. Dates,
part numbers/serial numbers of replaced parts, names of technicians, and other pertinent data should be
recorded.