Instruction Manual
9-4 Maintenance
9.5.1 Filling the Fluid Reservoir
CAUTION! Make sure to observe the fluid level indicator. Never let the dispensing system
run out of fluid as this may damage the fluid applicator.
To fill the Fluid Reservoir:
1. Turn the Reservoir Air Pressure Pneumatic Switch to the OFF
(0) position.
2. Relieve residual pressure in the Fluid System by opening the Fluid Pressure Relief Valve on
the Fluid Reservoir.
3. Open the lid and check that the reservoir is clean and free from foreign materials.
WARNING! Solvent vapors may be released when the lid is open.
4. Add fluid up to a maximum of 50 mm (2 in.) below the rim of the opening.
5. Close the lid immediately after filling.
Item Description
1 Reservoir Air Pressure Pneumatic Switch (right rear)
2 Fluid Pressure Relief Valve
Figure 9-1 Filling the Fluid Reservoir
1
2