Instruction Manual
Troubleshooting 8-1
8 Troubleshooting
8.1 Overview
If you have difficulty operating your dispensing system, use this section to identify a possible solution to
the problem. If you have difficulties not listed in this section, or the suggested solution does not correct
the problem, contact Asymtek Technical Support.
8.2 Basic System Troubleshooting
Table 8-1 Basic System Troubleshooting
Symptom Possible Cause Recovery
A. Main Power Cable
disconnected
Connect the Main Power Cable to an AC
power source.
B. Main Power Circuit
Breaker turned OFF
Turn ON the Main Power Circuit Breaker at
the rear of the system.
C. EMO is activated
1. Turn EMO clockwise until it releases.
2. Close doors.
3. Press Start button on Control Panel.
4. Press Find Home.
System does not
power-up when Start
button is pressed.
D. Machine Exhaust
Ventilation not ON
Make sure Exhaust Vent Duct is connected to
the factory exhaust system ductwork
according to specifications.
(600 scfm air at 1 in. water column static
pressure)
A. Tool offset incorrect
Reconfigure Tool and perform a
Characterization.
B. Nozzle is damaged Replace nozzle.
C. X, Y, Z location in ECXP
program is incorrect
Dispensing program may need to be edited.
Dispenses in the wrong
X, Y, and Z location.
D. Motors slipped
1. Press Dispenser Status Reset.
2. Wait three seconds.
3. Press Find Home.