Instruction Manual
7-10 Configuration and Characterization
5. Install the nozzle used to configure the tool on the Fluid Dispensing Applicator to teach the
Z-coordinate. See
Figure 7-8 for coordinate location.
a. To teach the Z-coordinate, carefully lower the nozzle until it is just touching the
surface of the board (Z-coordinate on the Side View) and
b. Click on the
Teach Z button.
Figure 7-8 Teaching XYZ Coordinates
X-Axis
Y-Axis
Z
Side View
Y
Top View
X
Z-Axis