Instruction Manual
6-26 Operation
6.9.3 Daily Routine Procedures
Table 6-6 contains a brief description and instructions for routine procedures that should be performed on
a daily basis before and after operating the dispensing system.
Table 6-6 Daily Routine Procedures
Procedure Description
STARTUP
Clean Fluid Filter
Check the fluid filter and clean if necessary. Refer to 9.5.4 Cleaning
the Fluid Filter.
Check Main Air Pressure
Ensure that the main air pressure is properly adjusted. If necessary,
adjust the main air pressure as described in 6.8.3.1 Main Air Regulator
and Gauge. Record the proper setting on the Daily Routine Checklist
for daily reference.
Check Fluid Pressure
Ensure that the fluid pressure is properly adjusted. If necessary, adjust
the fluid pressure as described in 6.8.3.3 Fluid Pressure Regulator and
Gauge. Record the proper setting on the Daily Routine Checklist for
daily reference.
"NOTE Refer to the manual for your specific fluid applicator
for appropriate fluid pressure settings.
Verify Exhaust Connection
Verify that the Exhaust Vent is properly connected to the facility
exhaust system ductwork. Refer to 4.11 Exhaust Connection.
Fill Fluid Reservoir
Fill the Fluid Reservoir as described in 9.5.1 Filling the Fluid Reservoir.
Fill Solvent Cup
Make sure that the solvent cup is filled with a clean supply of the
appropriate solvent and is properly placed for the selected coating
program.
Verify Material Temperature
Verify the material temperature, if applicable.
Perform Characterization
Perform a characterization if necessary. Refer to 7.5 Characterization.
SHUTDOWN
Remove Workpieces
Remove all workpieces and foreign objects from the dispensing and
conveyor areas.
Flush Fluid System
Flush the fluid system. Refer to 9.5.2 Changing Material/Flushing Fluid
System.
Clean Dispensing System
Clean all surfaces of the dispensing system (doors, side panels,
control panel, part sensor, etc.).
Clean Nozzle
Refer to the manual for your specific fluid applicator for instructions.