Instruction Manual

Power-up and Testing 5-15
Figure 5-13 ECXP Edit Screen - Conveyor Utilities Menu
5.9.1 ECXP Conveyor Utilities
In addition to the IO Tool described earlier in this section, the following ECXP commands, shown in
Table 5-3, may also be used to test and set up the Conveyor. To access the Utilities menu, click on
Edit > Edit Mode from the ECXP Operator Screen. To access the Conveyor Utilities commands, click on
Utilities > Conveyor Utilities from the ECXP Edit screen menu bar (Figure 5-13).
Table 5-3 ECXP Conveyor Utilities Commands
ECXP Command Description
Terminal
Displays a terminal window that is used to send ACL commands to the
Conveyor Controller.
Load Board
Requests a board from the upstream machine and loads it into the
workcell.
Unload Board Moves the current board on the Conveyor out of the workcell.
Restore Defaults Resets the Conveyor configuration parameters to the factory defaults.
Download File
Sends the designated file to the Conveyor Controller. The file is
immediately executed.
5.9.2 Inverter
If the Conveyor is equipped with an Inverter, use the following ECXP command to test the Inverter. To
access the Utilities menu, click on
Edit > Edit Mode from the ECXP Operator Screen. The command
described below is accessed from the ECXP Edit screen menu bar
1. Click on
Utilities > Inverter to move the currently loaded board into the Inverter.
2. Verify that the Inverter flips or rotates the board.