5-10 Power-up and Testing
To check function of the Fluid Pressure Regulator and Gauge:
1. Turn the Reservoir Air Pressure Pneumatic Switch to the ON
(l) position (Figure 5-9).
2. Locate the Fluid Pressure Regulator adjustment knob underneath the left side of the
front hood.
3. Unlock the knob by pulling it downward.
4. Rotate the Fluid Pressure Regulator adjustment knob counterclockwise until the Fluid
Pressure Gauge registers 0 psi.
5. Rotate the knob clockwise until the Fluid Pressure Gauge registers 60 psi (413 kPa).
TIP For accurate pressure adjustment, lower the pressure below the desired level and then
increase to the desired pressure.
6. Monitor the Fluid Pressure Gauge to make sure that pressure builds at a steady rate. Watch
for dropping pressure indicating an air leak.
! If there is an air leak, identify the source, shut off the facility air, and fix the leak before
proceeding.
7. Lock the knob by pushing it upward.
Item Description
1 Fluid Pressure Gauge (Control Panel)
2 Fluid Pressure Regulator
3 Reservoir Air Pressure Pneumatic Switch (Right Rear)
Figure 5-9 Fluid Pressure Pneumatic Controls