Instruction Manual

Power-up and Testing 5-9
To check function of the Stop/Clamp Air Regulator and Gauge:
1. Locate the Stop/Clamp Air Regulator adjustment knob at the rear of the dispensing system
(
Figure 5-8).
2. Unlock the adjustment knob by pulling it out.
3. Rotate the knob counterclockwise until the Stop/Clamp Air Gauge registers 0 psi.
4. Rotate the knob clockwise until the Stop/Clamp Air Gauge registers 55psi (379 kPa).
TIP For accurate pressure adjustment, lower the pressure below the desired level and then
increase to the desired pressure.
5. Monitor the Stop/Clamp Air Gauge to make sure that pressure builds at a steady rate. Watch
for dropping pressure indicating an air leak.
! If there is an air leak, identify the source, shut off the facility air and fix the leak
before proceeding.
6. Lock the knob by pushing it in.
Item Description
1 Stop/Clamp Air Gauge
2 Stop/Clamp Air Regulator
Figure 5-8 Stop/Clamp Air Regulator and Gauge
1
2