Instruction Manual
Power-up and Testing 5-7
To test the Conveyor I/O (C-740 only):
1. Follow the instructions in
5.4 Starting Easy Coat for Windows (ECXP) to start ECXP.
2. Select
Edit > Edit Mode from the ECXP Operator Screen menu bar to access the ECXP
Edit Screen.
3. Select
Utilities > Conveyor Utilities > IO Tool from the menu bar.
! A dialog box opens containing lists of Conveyor inputs and outputs, grouped by tabs.
4. Click on the I/O’s to verify that they are working properly (
Figure 5-6).
! Clicking on an input or output should toggle it ON or OFF.
Figure 5-6 Conveyor IO Tool
5. When you are done, select File > Exit from the menu bar or click on to return to the
ECXP Operator Screen.