Manual

Maintenance 7-3
Emptying the Water Trap
Moisture from the outside air can condense in the pneumatic system. The water trap
collects this condensed water, and you must empty it periodically, or whenever it is full.
WARNING!
Do not remove the steel bowl guard protecting the water trap.
The bowl is made of polycarbonate plastic, which could rupture if the
inside or outside of the bowl is exposed to chemicals
incompatible with polycarbonate.
To empty the water trap:
1. Locate the water trap at the rear of the system.
2. Disconnect the facility air supply from the Main Air Inlet.
3. Hold a container under the water trap to catch the water.
4. Using your finger, push the water drain knob at the bottom.
5. Reconnect the facility air supply to the Main Air Inlet.
End of Procedure
S
T
O
P
/
C
L
A
M
P
P
R
E
S
S
U
R
E
R
E
S
E
R
V
O
IR
A
IR
P
R
E
S
S
U
R
E
Figure 7-1 Water Trap
Drain Knob
Water Trap