6-6 Troubleshooting
Checking Part Sensors
To check the part sensors:
1. In the FmNT Main Window, click on Tools.
2. Click on I/O Test.
3. Click on Conveyor.
This opens the Test Window, which displays a list of all inputs and outputs.
4. Turn the Interlock ON (I).
5. Press
Pause on the Control Panel.
WARNING!
Wait for all dispensing head and conveyor motion to stop before
opening the doors.
6. Open the doors.
7. Manually move a board into the Pre-dispense or Dispense Zone until it is directly over
the sensor (see Figure 7-3).
> For left-to-right conveyors, watch the Left Sense I/O in the Test Window.
> For right-to-left conveyors, watch the Right Sense I/O in the Test Window.
> If either the Left or Right Sense I/O does turn ON, the sensor is functioning.
> If both the Left and Right Sense I/O’s fail to turn ON, the sensor is not
functioning.
Call a service technician.
End of Procedure