Troubleshooting 6-5
Conveyor Troubleshooting
Table 6-2 Conveyor Troubleshooting
Symptom Possible Cause Recovery
1. Stop Pins and/or
clamps do not work.
Air pressure too low.
Check main air pressure (80-90psi)
and conveyor air pressure (30-40psi).
2. No up/downstream
interface.
Varies. Call a service technician.
3. Part sensors not
sensing when board
is present.
Sensors are dirty, not
active or are out of
adjustment.
§ Clean Part Sensors
§ See Checking Part Sensors, p. 6-
6.
4. Board will not index
after dispensing.
No SMEMA signal from
downstream system.
Call a service technician.
A. Stop pins not
receiving air.
Call a service technician.
B. PCB Sensor dirty Clean PCB Sensor
5. Board will not index
to correct position.
C. Conveyor rails gap
too narrow
Check conveyor width
6. Conveyor does not
move at all (with
software or Control
Panel).
Conveyor module
(201W) has no power.
1. Verify that the AC power cable is
connected to the module and to
the facility power source.
2. Check 2A fuse on 201W module.
7. Fails to find width
Home.
Personality parameters
are corrupt.
Call a service technician.