Manual

Operation 4-29
To adjust the fluid pressure:
1. Verify that the dispensing system is ON.
> The System Status LED and Light Beacon should be yellow or green.
2. Open the front doors.
> The green System Status LED and Light Beacon will turn yellow.
3. Rotate the regulator counter-clockwise to set the fluid pressure to 0 kPa. (0 psi).
4. While watching the gauge, rotate the regulator clockwise or counter-clockwise as
applicable.
> Clockwise (right) to increase pressure up to the desired level.
> Counter-clockwise (left) to decrease pressure. To avoid false readings, lower the
pressure past the target level, then rotate the regulator clockwise (right), to raise
pressure up to the desired setting.
End of Procedure