Manual
4-26 Operation
Fluid and Valve Fittings
The pneumatic fittings for the fluid and valve pressure are located on the right side of the
dispensing head (see Figure 4-11).
Table 4-9 Fluid and Valve Pneumatic Fittings
Fitting Color Description
Fluid Pressure Clear
Provides Nitrogen Air pressure to
the syringe.
Valve Pressure Black
For DJ-2200—Provides regulated
air pressure to the valve.
Coaxial Air Green
Provides regulated air pressure to
the coaxial air nozzle.