4-14 Operation
Table 4-5 System Status Control Functions (Continued)
Button/Indicator Function
V1V1
VALVE
STATUS
V2
VALVE STATUS LED turns ON if there is a problem
with the fluid pump motor. It usually indicates that the
pump electronics (overcurrent protection circuitry) has
detected a surge of power. When the LED is ON, the
valve is disabled. V1 is Valve 1. V2 is Valve 2.
To recover, press VALVE RESET. If the problem
persists, the pump may need to be cleaned.
VALVE
RESET
Press VALVE RESET you have corrected any
problem indicated by the Valve Status indicators.
APPLIC
ON/OFF
Press APPLIC ON/OFF to turn applicator operation on
and off. Can be used to run a dispensing program in
“dry mode.”
PURGE
This button is non-functional in the C-730 Flux
dispenser. The purge function is executed through the
software interface.